Project Description

REPORTS

We offer a range of reporting including AESMR, Hydrant System Hydrostatic Tests and Hydrant System Commissioning Test Reports.

SERVICE INFORMATION

Annual Essential Safety Measures Reports

An AESMR (Annual Essential Safety Measures Report) is a report that is required to be completed annually by the owner of all commercial buildings, or places of public entertainment, in relation to all essential safety measures in that building.

The report will include all Essential Safety Measures items as listed on the building’s occupancy permit. Prior to July 1994, these Essential Safety Measures were not listed on permits, in this case we will include all existing Essential Safety Measure items that have been identified, or provided in a maintenance schedule.

The AESMR is required to confirm that, for the preceding 12 months, the owner has taken all reasonable steps to ensure that each essential safety measure is operating at the required level of performance or is fulfilling its purpose.

Fire Marshall specialise in this area of compliance and can provide an AESMR for all of your buildings, the format of our reports comply with all regulatory requirements and satisfy your requirements as a building owner.

If you require an AESMR, or have a related compliance query, please contact our Compliance Manager today.

Hydrant System Hydrostatic Test Report

In order for fire fighters to extinguish a fire effectively, hydrants must be able to achieve a minimum flow rate. Flow testing involves measuring the static (normal operating) and residual pressures of the most disadvantaged hydrant, identifying weak points in the system, and determining whether certain arterial mains may require maintenance. The most important objective however, is to make sure that the minimum flow rate can be achieved in order to fight a fire.

Fire Marshall’s service includes a 2 hour hydrostatic test of the hydrant system, an overall inspection, and a full report of the test results, findings and recommendations (if any).

Hydrant System Commissioning Test Report

New installations and alterations to existing systems must conform to Australian Standards and the Building Regulations 2006. The purpose of a commissioning test is to ensure that the system design and installation of fire hydrants produces a system that is fully functional in any fire situation.

Fire Marshall’s service includes an full inspection of the fire service to ensure that it has been installed correctly, a hydrostatic / flow test, and a report to summarise the test results, findings and recommendations (if any). Fire Marshall also supply and install signage, 003 locks and valve identification tags required for commissioning compliance.

Certificate of compliance also requires a block plan to be displayed in the booster cabinet that outlines the fire system layout and capabilities. For more information on block plans click here.

Contact Us

As the risk of fire is always there, your fire detection systems need to be ready to perform when you need them most

Through our regular comprehensive servicing and maintenance services, our technicians aim to provide properly functioning fire equipment and systems. We service a huge range of fire protection systems for organisations large and small, we maintain all brands of various manufactured equipment.

Rapid Response and a 24/7 Support that comes to you

Fire Marshall provides you with a fast and effective response. We have highly trained field staff, So when the heat is on, you can count on us to be there for you.

Fire Marshall Service Technicians are on 24-hour standby; ready to undertake emergency repairs to your fire-protection systems and products. Our teams are equipped with self-contained vehicles and mobile technology that enables them to deal with most service problems on the spot.

  • Minimal disruption
  • Compliance Testing Reports
  • Rapid response
  • 24/7 support that comes to you

SERVICE INFO

Fire Protection Maintenance 100%
24 Hour Support 100%

NORMAL HOURS

Week Days 8:00 – 4:00
Saturday By Appointment
Sunday By Appointment

  (03) 9775 0913

LOCATION

Contact Us

OTHER SERVICES

Fire Marshall is your one stop Fire Protection Service Provider

Design

Evacuation Diagrams are an essential part of your Emergency Plan for your workplace.

READ MORE

Reports

We offer a range of reporting including AESMR, Hydrant System Hydrostatic Tests and Hydrant System Commissioning Test Reports.

READ MORE

Electrical

Fire Marshall offer a wide range of electrical services to cater for your domestic, commercial and industrial needs.

READ MORE

Training

Fire Marshall offer various fire training courses to assist with your work place Occupancy, Health and Safety needs.

READ MORE

Testing

Click to see an outline of the test services that Fire Marshall offer and an indication of the service frequency.

READ MORE

SERVICE GUARANTEE

With over 40 years of experience in the fire protection industry, Fire Marshall strives to provide service that delivers integrity and confidence. We are a family owned business and these values are important to us. Whether it’s safety in the home, or a small business or multi-corporation, Fire Marshall is dedicated to providing the highest level of service to our customers.

FREE QUOTE

Do you need help with Fire Protection Services? Fill out this form to get in touch.

      OFFICE LINE

      (03) 9775 0913

      (07) 3278 8836

      EMERGENCY VIC 24/7

      0408 059 838

      EMERGENCY NSW + QLD 24/7

      0483 226 010

      OFFICE HOURS

      8:00am – 4:00pm

      OFFICE LINE

      (03) 9775 0913

      (07) 3278 8836

      EMERGENCY VIC 24/7

      0408 059 838

      EMERGENCY NSW + QLD 24/7

      0400 837 719

      OFFICE HOURS

      8:00am – 4:00pm